Wires and clocks
Verge speaks SWD, JTAG and cJTAG (IEEE 1149.7). It frames cJTAG in four scan formats: OScan1, OScan2, OScan5 and OScan6. NXP's firmware has no cJTAG.
Hosts#
Any CMSIS-DAP host drives SWD and JTAG, as it drives NXP's firmware.
cJTAG takes a host that knows it. The host selects a scan format with vendor command 0x95
(Host interface) and connects over JTAG, and the probe
frames in that format from the connection on. Then the host activates the target and switches it to
the same format. verge read --protocol cjtag reads target memory over cJTAG, through a probe-rs
branch that drives the commands proposed for CMSIS-DAP. No probe-rs release has cJTAG for
CMSIS-DAP probes.
From the clock asked for to the clock on the wire#
The probe's core runs at 150 MHz, and every wire period is a whole number of its cycles. So the
probe rounds the clock a host asks for down to the next step it can make: 30 MHz is 5 cycles, 18.75
MHz is 8. A request above the fastest clock gets the fastest. A request below 9 Hz gets DAP_ERROR,
and the clock stays as it was: its period would be more than 2^24 core cycles, longer than the
probe's transfer code can wait.
Every transfer runs on code the probe generates at runtime, for the clock and the settings in use (Code generation).
When the probe measures the target#
The probe samples a target's reply at a fixed delay after the clock edge that asks for it: the
target's read latency. It measures that latency on the wire before it trusts a sample position: when
a host connects at a fast clock, when a connection's first read fails, and when the host changes the
clock. On a board that can capture energy, a connection also measures at any clock where a capture
starting or stopping would change which latencies the code serves. A measurement that contradicts
itself runs again. Verge's own tools can ask for one, or pin the latency, and a pinned latency is
never measured (Host interface, 0x89 and
0x8A).
SWD#
A write clock takes 3 core cycles and a read clock 4. So asked for 50 MHz, a transfer's request and write data run at 50 MHz, and its read data at 37.5 MHz. The target's reply delay slows neither.
On the Pro, energy capture slows reads. While a capture runs, a read clock takes at least 5 cycles (30 MHz), or 6 for some reply delays. The capture's DMA can delay the probe's read of SWDIO by two cycles, and a 4-cycle clock leaves no room for that. The DMA can delay a write's store too, so a few write clocks take 4 cycles instead of 3.
After an acknowledge other than OK, the probe still clocks the transfer's data phase, as ARM's
firmware does: always after a protocol error, and after WAIT or FAULT when the host has turned the
data phase on (DAP_SWD_Configure). Those clocks run at 25 MHz at most. A
latency measurement reads at sample positions that can miss
the acknowledge, so a recording of a connection at 50 MHz can show a few reads whose data runs at
25 MHz.
JTAG#
The probe has to sample TDO after the target drives it, so a slow target lengthens the clock. The probe measures that delay (When the probe measures the target), and the delay sets the clock:
| the target's TDO delay, in core cycles | the clock |
|---|---|
| up to 8 (53 ns) | 30 MHz |
| 9 or 10 | 25 MHz |
| 11 | 21.4 MHz |
| 12 | 18.75 MHz |
| 13 | 16.7 MHz |
| 14 | 13.6 MHz |
| 15 or 16 | 12.5 MHz |
Past 16 cycles, each cycle of delay adds one core cycle to the clock. A CC1312R1 measures 7 after a pin reset, and 10 right after a system reset.
On the Pro, energy capture can make these clocks up to two cycles longer while it runs: its DMA can
delay the probe's read of TDO by two cycles. At 7 cycles of delay, DAP_Transfer and
DAP_TransferBlock keep 30 MHz with a few clocks at 25 MHz, and DAP_JTAG_Sequence scans at
25 MHz. At 6 cycles both run at 25 MHz, at 8 at 21.4 MHz, and at 9 or 10 at 18.75 MHz.
cJTAG#
The wire carries packets at up to 50 MHz, and in OScan1 three packets make one JTAG clock. The probe samples TDO one cycle past the delay it measures, and each cycle of delay adds one core cycle to the frame. A CC1312R1 measures 7 in every format, so its OScan1 frame takes 19 core cycles: 7.9 MHz of JTAG clock.
The other formats send fewer packets for some clocks:
- OScan2 sends a clock outside Shift-DR and Shift-IR as a single packet.
tools/dap.py, a host in mculink-verge that drives the probe directly, reads a CC1312R1 6% faster in OScan2 than in OScan1 at 12.5 MHz, 4% faster at 25 MHz, and level with it at 50 MHz. - OScan5 sends a clock in Shift-DR and Shift-IR as two packets, the last of them leaving with an escape. On a CC1312R1 that frame takes 16 core cycles: 9.4 MHz. dap.py reads a CC1312R1 27% faster in OScan5 than in OScan1 at 12.5 MHz, 18% faster at 25 MHz and 5% faster at 50 MHz, where USB starts to set the rate.
- OScan6 sends a clock outside Shift as one packet, and a clock in Shift as OScan5 does. On a CC1312R1 it reads 10% faster than OScan5 at 12.5 MHz, and level with it from 25 MHz.
verge connects in OScan1 unless asked for another format (verge read --cjtag-format). Ask only
for a format the target has: the probe frames in the format the host selects, and neither verge nor
probe-rs reads the target to check. The target's documentation, or its CNFG0 register, says which
formats it has: cJTAG targets says how to read it on TI's parts.
We have not tried a target without the asked format. cJTAG has the wire in detail.
Limits#
The table gives the fastest each transport runs, Verge beside NXP's firmware V3.174, from runs between 2026-11-04 and 2026-11-14. Verge's figures hold for the current firmware. The measurement log says how and when each was taken.
| Transport | Verge | Verge's rate depends on | NXP's firmware V3.174 |
|---|---|---|---|
| SWD writes | 50 MHz | The Pro's energy capture: a few clocks at 37.5 MHz while it runs | 10.7 MHz |
| SWD reads | 37.5 MHz | The Pro's energy capture: 30 MHz while it runs | 10.0 MHz |
| JTAG (reads and writes) | 30 MHz | The target's TDO delay; the Pro's energy capture | 5.4 MHz when asked for 10 MHz; fails from 12.5 MHz |
| cJTAG (reads and writes) | 50 MHz per wire packet; per JTAG clock in Shift, 7.9 MHz in OScan1 and OScan2, 9.4 MHz in OScan5 and OScan6 | The target's TDO delay | No cJTAG |
| Console (VCOM) | 30 Mbaud | Nothing | 4 Mbaud |
| SWO | 30 Mbaud, UART encoding only | Nothing | Not measured |
| USB | High speed, 512-byte packets, 3 commands held | The host's port: 64-byte packets on a full-speed one | 512-byte packets, 8 commands reported |
The cJTAG row is a CC1312R1's, which measures 7 cycles of delay. NXP's SWD figures are data-bit
rates at requests of 25 MHz and above, where they stop rising. At those requests its reads were not
always right: probe-rs read 64 KiB of flash right 8 times in 10 at 25 MHz and 9 in 10 at 50, and
queued commands failed at 50 MHz. At 10 and 20 MHz every read was right. NXP's JTAG clock is the
median of an uneven one: its 5th to 95th percentile periods were 140 and 233 ns. NXP's console
figure is the fastest both of the Pro's ports ran at once without loss. NXP's USB figures are what
DAP_Info reports; how many commands its firmware holds was not measured.
Trace and serial ports says how the console and SWO rates were reached. mculink-bench's measurements page compares throughput through the same probe-rs workload, on the same target, with NXP's firmware and a SEGGER J-Link Ultra. Its figures come through probe-rs 17beb8e80, a build of the project's fork with changes for speed that the probe-rs under verge does not have.
Past NXP's limits#
Some of these rates are past NXP's specifications. They passed the tests in Trace and serial ports. The host asks for the rate, so whoever runs the probe decides whether to use them.
| Feature | NXP's limit | Verge past it |
|---|---|---|
| Console | The UART is specified to 10 Mbit/s (LPC55S6x data sheet, 7.26.3.4) | Above 10 Mbaud: 12, 16, 19.2, 21.4, 25 and 30 Mbaud ran clean |
| Console | The UART's clock divider is specified to 100 MHz (UM11126, 4.5.49) | For a rate the 96 MHz clock cannot make within 3%, such as 10 Mbaud: 10, 21.4, 25 and 30 Mbaud ran clean with it at 150 MHz |
| SWO | The same UART, to 10 Mbit/s | Above 10 Mbaud: 12, 16, 24 and 30 Mbaud ran clean |
| SWO | The UART's clock divider is specified to 100 MHz (UM11126, 4.5.49) | Above 20.1 Mbaud, where nothing inside the divider's limit comes within 0.5% of the rate: 21.4, 24, 25 and 30 Mbaud ran clean with it at 107 to 150 MHz |
From mculink-verge, where changes to this page go.